福禄克Fluke OptiFiber? Pro?OTDR系列
福禄克Fluke CertiFiber?光纤损耗测试套件
福禄克Fluke SimpliFiber? Pro光功率计和光纤测试仪
福禄克Fluke Fiber QuickMap?多模光纤距离和故障定位仪
福禄克Fluke Fiber OneShot? PRO光纤测试仪
福禄克Fluke VisiFault? Visual Fault Locator电缆连通性测试仪
福禄克Fluke MultiFiber? Pro光功率计及光纤测试工具包
福禄克Fluke FI-7000 FiberInspector? Pro光纤显微摄像机
The BM15 and MJ15 are compact 5kV insulation testers. They are very simple to use and provide a quick and accurate reading of insulation resistance. The instruments use an analog display with a maximum reading of 20 GΩ.
Four test voltages to 5 kV
BM15 battery powered. MJ15 hand cranked and optional battery powered.
Voltage range to 600 V indicates auto discharge
Pass/fail overlays for rapid testing
DESCRIPTION
The Megger? BM15 and MJ15 are compact 5 kV insulation testers. They are very simple to use and provide a quick and accurate reading of insulation resistance. The instruments use an analogue display with a maximum reading of 20 GΩ. The BM15 is powered by batteries. The MJ15 has an additional hand-cranked generator.
The instrument operation is extremely simple. A voltage range enables measurement of a.c. or d.c. conductor potential. Four test voltages are available at 500 V, 1 kV, 2,5 kV and 5 kV. A choice of push buttons is supplied; a locking button simplifies long term testing, or a nonlocking version is preferred for maximum safety.
A bezel allows a scale plate overlay to be added with pass/fail bands for go/no go testing. This is particularly useful for less experienced users and enables a rapid decision to be made.
The new instruments have a choice of power source. The BM15 is powered by 8 x LR6 (AA) alkaline cells. The MJ15 comes with a hand cranked generator plus batteries. If the test button is pressed the MJ15 uses battery power. Otherwise the crank handle is turned to save battery power or for use when the batteries are unavailable.
Both units are built into a rugged case designed for outdoor use. The instruments are also supplied with a soft carrying case, a test lead set, test record cards and batteries.
Safety terminals suitable for locking connectors are used for connection to the test piece. An automatic discharge circuit eliminates the voltage on capacitive loads after a test. The decaying voltage can also be viewed on the scale.
Fused test leads are available as an option for voltage measurement. The instruments meet the IEC1010 safety specification and EMC specifications and are fully CE marked.
APPLICATION
Insulation is important for the safety of all electrical systems, providing a barrier to hazardous live conductors. Insulation can deteriorate due to the affects of moisture, sunlight and heat. A reduction in the value of insulation resistance can lead to a potentially dangerous situation caused by the dangers of electric shock, or arcing causing fire. If insulation resistance is regularly monitored unusually low values can be investigated before they cause danger, or inconvenience and cost due to equipment downtime for repairs.
The BM15 and MJ15 are general purpose, 5 kV insulation testers for electrical contractors and engineers who test machinery, transformers, switchgear, cables, etc.
This product is used by:
Electrical Contractors
Maintenance Engineers
Telecommunications Engineers
Gas and Water Utilities
Railway Companies
Cable Manufacturers
Mining Companies